■ Smart pressure transmmitter model APC-2000 ALW
■ Smart pressure transmitter model APCE-2000PD and APCE-2000PZ
■ Pressure transmitter model PCE-28
■ Level measurement APC-2000ALW
■ Smart differential pressure transmmitter model APR-2000 ALW
■ Smart differential pressure transmmitter model
APRE-2000PD and APRE-2000PZ
■ Smart pressure transmitter for low ranges model APRE-2000G
■ Smart differential pressure transmitter for low ranges model APR-2000G AL
■ APR-2000ALW,APRE-2000 with direct diaphragm seal
■ Smart differential pressure transmmitter with remote diaphragm seals model APRE-2200...
|
| |
Page [1] [2] |
|
|
|
| |
Smart pressure transmmitter model APC-2000 ALW
|
|
|
|
|
|
|
|
Measuring range: min. 0 ... 1 mbar; max. 0... 1000 bar
Output signal: 4...20 mA, 0...20 mA or 0...5 mA + protocol HART; Profibus PA
Accuracy: 0,075%
bcProcess connection: M20 x 1,5; G 1/2"; G 1/2" (flush diaphragm);
G 1" (flush diaphragm); M30 x 2 (flush diaphragm);
M20 x 1,5 (flush diaphragm);
Diaphragm seals; [ Download PDF ] |
|
 |
 |
|
 |
|
 |
|
 |
|
| |
|
|
| Smart pressure transmitter model APCE-2000PD and APCE-2000PZ |
|
Top |
|
|
|
|
Measuring range: min. 0 ... 1 mbar; max. 0... 400 bar
Output signal: 4...20 mA + protocol HART
Accuracy: 0,1% (0,075%)
Process connection: M20 x 1,5; G 1/2"; G 1/2" (flush diaphragm);
G 1" (flush diaphragm); M30 x 2 (flush diaphragm);
M20 x 1,5 (flush diaphragm);
Diaphragm seals; [ Download PDF ] |
|
 |
 |
|
 |
|
|
|
|
|
| |
|
|
| Pressure transmitter model PCE-28 |
|
Top |
|
|
|
|
Measuring range: min. 0 ... 10 mbar; max. 0... 1000 bar
Output signal: 4...20 mA, 0...10 V
Accuracy: 0,2% (0,16%)
Process connection: M20 x 1,5; G 1"; G 1/2" (flush diaphragm);
G 1" (flush diaphragm); M30 x 2 (flush diaphragm);
M20 x 1,5 (flush diaphragm);
Diaphragm seals; [ Download PDF ] |
|
 |
 |
|
| |
|
| |
|
| |
|
| |
|
|
| Level measurement APC-2000ALW |
|
Top |
|
|
|
|
Smart or analog differential pressure transmitters with diaphragm seals for level measurement
- to pressure tank with gas-filled negative pressure line are recommended
transmitters with diaphragm seal mounted on "+" side
- to pressure tank with liquid-filled negative line are recommended transmitters with diaphragm seal mounted on "-" side and converted output signal. [ Download PDF ] |
|
 |
 |
|
 |
|
 |
|
| |
|
| |
|
|
| Smart differential pressure transmmitter model APR-2000 ALW |
|
Top |
|
|
|
|
Measuring range: min. 0 ... 4 mbar, max. 0... 16 bar
Output signal: 4...20 mA, 0...20 mA or 0...5 mA + protocol HART; Profibus PA
Accuracy: 0,075% [ Download PDF ] |
|
 |
 |
|
 |
|
 |
|
 |
|
| |
|
|
Smart differential pressure transmmitter model
APRE-2000PD and APRE-2000PZ |
|
Top |
| |
|
|
|
|
Measuring range: min. 0 ... 4 mbar, max. 0... 16 bar
Output signal: 4...20 mA + protocol HART
Accuracy: 0,1% [ Download PDF ] |
|
 |
|
 |
|
 |
|
| |
|
| |
|
| |
|
|
|
|
| |
Smart pressure transmitter for low ranges model APRE-2000G |
|
Top |
|
| |
|
|
|
|
Measuring range: min. 0 ... 0,2 mbar, max. 0... 100 mbar
Output signal: 4...20 mA + HART
Accuracy: 0,1% (1%)
Process connection: to fi 6x1 pipe, mounted with a valve manifold [ Download PDF ] |
|
 |
|
 |
|
 |
|
| |
|
| |
| |
| |
|
|
|
|
| |
Smart differential pressure transmitter for low ranges model APR-2000G AL |
Top |
|
| |
|
|
|
|
Programmable zero shift and damping ratio
Selectable linear or radical conversion characteristic
Output signal: 4...20 mA + HART
Accuracy: 0,1% (1%) [ Download PDF ] |
|
 |
|
 |
|
 |
|
|
|
|
|
| |
|
|
|
|
| |
APR-2000ALW,APRE-2000 with direct diaphragm seal |
Top |
|
| |
|
|
|
|
Smart or analog differential pressure transmitters with diaphragm seals for level measurement
- to pressure tank with gas-filled negative pressure line are recommended
transmitters with diaphragm seal mounted on "+" side
- to pressure tank with liquid-filled negative line are recommended transmitters with diaphragm seal mounted on "-" side and converted output signal. [ Download PDF ] |
|
 |
|
 |
|
 |
| |
 |
| |
| |
| |
| |
|
|
|
|
| |
Smart differential pressure transmmitter with remote diaphragm seals model APRE-2200... |
Top |
|
| |
|
|
|
|
Measuring range: min. 0 ... 0,1mH2O, max. 0... 16 bar
Output signal: 4...20 mA + protocol HART; Profibus PA
Accuracy: 0,1% [ Download PDF ] |
|
 |
|
 |
| |
 |
| |
 |
| |
| |
| |
| |
Page [1] [2] |
|
|
|
| |
|
|
|
|